Documented ProcedureBPA
D o c u m e n t e d P r o c e d u r e
MPZ 001
4100-001-06.05
Department TB / Schell
Servo Line
Page 10 24
Rev. Index D Name 01.06.05 Schell
Date 3.05.2011 released 01.06.05 Lorch
MPZ_001_engl.doc
Mounting instructions
Contact surface
Hexagon socket screws 12.9
M6 M8 M12
M16
M20
M30
M36
Tightening torque in Nm
16 40 135
340
660
2300
4100
Tightening torque in lbf in
142
354
1195
3010
5842
2. Insert the mating companion piece over the joint so that it meshes with the teeth of
the two racks and fix it on the opposite using a suitable contact surface.
Contact surface
No supporting surface available
Mating
piece
Suitable
contact surface
The machine bed should enable easy installation and
grease-free mounting of the rack.
1. Position the first rack on the machine bed, adjust it
concentrically, and clamp it to the contact surface with a
screw clamp. Insert the hexagon socket screws without
fully tightening them yet. Adjust the supporting surface of
the rack in relation to the machine guide. Then tighten the
hexagon socket screws as shown in the torque table
below, beginning in the middle and continuing outwards.
The screw clamps may be removed.
Fit the second rack at the joint and
clamp it with screw clamps
against the contact surface of the
machine bed. Insert the hexagon
socket screws and tighten them
slightly so that aligning is still
possible. The screw clamps may
be removed.
Comentários a estes Manuais